Safety Concerns with Heat Exchangers

Author : New Jersey Home Inspector Michael Del Greco
Safety Concerns with Heat Exchangers

Submitted by: Michael Del Greco, New Jersey Home Inspector Lic GI 0121, President of Accurate Inspections, Inc, a New Jersey home inspection company

How unsafe is a failed heat exchanger in your forced-air system? The main safety concern with warm-

air furnaces, sometimes called \"hot air heat,\" is keeping the products of combustion from mixing with

the air in the home and negatively affecting the health of the occupants.

When fuel is burned, three products are produced: (1) heat, (2) carbon dioxide (C02), and water (H20).

This example assumes complete combustion. If there is incomplete combustion, other products will also

be present. These may include the compounds such as carbon monoxide (C0), formaldehyde (HCH0)

and numerous other aldahydes, nitrogen dioxide (N02), and sulfur dioxide (S02). The technicians who set up furnaces try to keep the C0 to less than 100 parts per million (ppm) in the exhaust.

Problems develop when there is a blocked or partially blocked chimney and/or a failed heat exchanger.

A blocked chimney can fill the area where the heater is located and the first floor with toxic C0 gases in

a few hours, depending on how much air flow there is in the house. In most situations, a blocked chimney is relatively easy to clear.

A failed heat exchanger is much more difficult to determine, but, in almost all cases, is much less
dangerous than a blocked chimney. In fact, when the furnace\'s fan is running, the heat exchanger is pressurized from the house air side. In almost all cases, this pressure will not allow dangerous gases to

accumulate in the house air. The path of least resistance for these exhaust gases is up the chimney.

This may not be the opinion of most gas utilities in the country, which is somewhat understandable based on the liability exposure.

The pressure on the heat exchanger has a significant effect on the tendency of flue gases to pass from
one side of the heat exchanger to the other. If the fan is off, the pressure from the burner will cause the burner side to be positive and the C0 or C02 gas can pass to the house side. The amount of gas passing

from one side to the other is based on the size and location of the failure in the heat exchanger.

However, it is rare this amount would exceed the amount of C0 or C02 gases emitted from a kitchen gas range flame.

When the fan comes on, the house air side of the heat exchanger, in almost every case, is positive. The positive pressure from the house air or fan side would cause the house air to be pushed into the exhaust

side, not vice versa. The only exception may be some power burners which would maintain positive pressure on the burner side while the fan was on or a heat exchanger failure which was large enough to

get your fist into.

The main thing to remember is that high pressure will always move to a low pressure. There are a few other factors which must be added to be totally accurate. These would include the location of the failure and the design of the heat exchanger.

I am not trying to say that failed heat exchangers are safe, but would like you to know it is rarely as

much of a concern as we hear from most information sources.



One last item: According to the American National Standards, it is almost impossible to construct a heat exchanger that is entirely air tight. Therefore, any test method developed to detect flue gas leakage

needs to have quantitative aspects. It would not be desirable to identify as unacceptable any heat exchanger leakage that meets the equirements/standards for heat exchanger joints. This standard says the leak should not be more than 2% of the flue gases with the internal pressure raised to .1 water
column (WC) static pressure.



Information provided by Michael Del Greco, New Jersey Home Inspector Lic. GI 0121, American Society of Home Inspectors Member 102273, Pesident of Accurate Inspections, Inc. A West Paterson New Jersey Home Inspection firm.

Spam emails More free articles

Related articles


  1. How To Save Your Fruit Tree Blossoms From A Spring Freeze.
  2. Planting Roses - Tips And Ideas To Ensure Beautiful Results
  3. Helpful Ideas For Designing A Flower Garden
  4. Fertilizing Your Flowers And The Importance Of Choosing The Right Flower Food
  5. Choosing The Perfect Flowers For Summer
  6. The Best Flowers For Spring
  7. The Great History Of Roses
  8. How to choose your garden furniture and make it last
  9. Garden Leaf Blower Maintenance
  10. Garden Composting Tips- The Art of Composting
  11. Types Of Lawn Mower Batteries
  12. Mulching Benefits / Organic And Inorganic Mulch Types
  13. Soil Basics - Creating Fertile, Healthy Soil
  14. Everyone Needs A Spaghetti Garden
  15. Fall Planting
  16. Soil PH And Its Effect On Your Garden
  17. Caring For Christmas Trees
  18. It's Time To Select Your Snow Blower
  19. How to make your landscape look good.
  20. Introduction to bonsai tree growing: an overview
  21. How to Grow Wildflowers
  22. Make Your Fresh Cut Roses Last Longer!
  23. Bonsai Soil And Additives
  24. Tips For Buying Lawn Tractors
  25. Gifts for the Gardener
More related feeds
Carrier gas furnace short cycling - DoItYourself.com Community Forums
In a different forum I read about scale in the heat exchanger could indicate a problem, or a cracked heat exchanger allowing air in at the wrong place, and not allowing the air flow to cool the furnace causing the high limit to open. ...

Design & Optimization | Avoid Costly Design Mistakes | Chemical ...
In today’s chemical industry, too many engineers given the task of specifying welded equipment such as vessels, heat exchangers and tanks aren’t well versed in what’s necessary to develop an economic design that provides suitable safety ...

Watch Idaho Nuclear Project to Gauge Obama's Energy Plan - 2008-11 ...
There are many issues. One is the need for development of a material to be used in a lynchpin of the concept: an intermediate heat exchanger. Existing materials don't meet the requirements for intense heat and pressure. ...

Bell Gossett Names New Representatives for Southeastern United ...
About Bell & Gossett Bell & Gossett, a brand of ITT, is a leading manufacturer of centrifugal pumps, hydronic specialties, heat exchangers, condensate handling equipment, and packaged systems for variable and constant speed pumping, ...

Heat Exchangers
Sharpsville Container specializes in the manufacturing of corrosion resistant heat exchangers and immersion heater technologies. Our team of engineers can assist with the design to meet any custom application that you may need. ...

Should you Repair or Replace your Boiler?
Key features include cast aluminium-silicon heat exchanger, brass waterset, efficient pump, and a concealed system connection that enhances performance of the product. A centrally located telescopic flue kit with preformed connections ...

repair (heat xchgr) or replace (furnace) - DoItYourself.com ...
... heat exchanger is not a leaking heat exchanger. If the furnace is clean and the heat exchanger is not leaking it is not bad and furnace replacement should be a choice made for cost/benefit reasons not out of fear or safety concerns. ...

Heat exchanger leaking in 2001 Toyota Camry. How to diagnose ...
Does this car have a Heat Exchanger thats gone bad ?? or another part in the Heater portion of the car ?? help not sure where to check. I would like to try and fix it myself if possible to save some $$$$$. thank you.

Heat Exchanger World: Avoid Premature Heat Exchanger Failure With ...
The main component for both hot water and forced air heating units is called a heat exchanger. The purpose of this nifty component is to take the heat that is produced by burning fuel in your furnace, and to transfer it into the water ...

Welding Handbook
Includes guides on how to choose the right welding equipment tools, oxygen-acetylene welding, heating and cutting, arc welding, MIG (wire-feed) welding, TIG (Heli-arc) welding, plasma-arc welding and cutting, safety and shop equipment. ...

 


 

© 2007 articlesreader.com - All Rights Reserved