Tracing the Accuracy of Calibration Gases

Author : R. L. Fielding

Regardless of how you use specialty gas mixtures to calibrate a
laboratory instrument or monitor, the most important thing you
can do to ensure the accuracy of your measurements is to ensure
the accuracy of your gas mixture. Gas mixture accuracy, in
turn, is largely dependent upon its analytical traceability to a
reference material. For analytical traceability to exist, there
must be an unbroken link of comparison between the measured
value of the gas mixture and a reference that is recognized in
the national or international measurement system as being a true
value. Thus, analytical traceability is the link between the
analyzed concentration and the true concentration of a gas
mixture. The National Institute of Standards and Technology
(NIST) provides Standard Reference Materials (SRMs) for this
purpose. Another such metrological organization, the Netherlands
Measurement Institute (NMi), provides Primary Reference
Materials (PRMs).

Analytical traceability is achieved by laboratory analysis of a
mixture using an instrument that has been directly calibrated
using either an SRM or a PRM. A mixture analyzed in this manner
is said to be "directly traceable." SRMs and PRMs are at the top
of the traceability hierarchy and add the least amount of
uncertainty to a mixture analysis because they are individually
analyzed and certified by NIST or NMi laboratories.

Since 1995, NIST and NMi have maintained an equivalence
agreement in those cases where comparative analyses have been
completed by the two labs. Because of this NIST/NMi equivalency,
traceability to a PRM is considered the legal equivalent of an
SRM.

Direct analytical traceability can also be established using
what are known as NIST Traceable Reference Materials (NTRMs).
NTRMs are produced by gas suppliers and then batch analyzed and
audited by NIST against the same internal standards as SRMs.
NTRM values are assigned by NIST and offer nearly the same
accuracy confidence level as SRMs and PRMs in most cases.

The high cost of producing SRMs and PRMs make it economical for
some specialty gas suppliers to blend intermediate standards
called Gas Manufacturer Intermediate Standards (GMISs). Though
they are analyzed against existing SRMs, they are at the bottom
of the traceability hierarchy. A GMIS introduces more
uncertainty because more steps are involved and because NIST is
not involved in either their analysis or certification. The gas
supplier is responsible for assigning the concentration and
accuracy, based solely on their analysis.

Gas mixtures that are produced using GMISs do not provide direct
NIST-traceability, and so may not be suitable for some
applications. For example, the EPA requires that a Continuous
Emission Monitor be calibrated using a protocol that is at least
as accurate to within ฑ2%. Use of a protocol that was prepared
using a GMIS may not guarantee such accuracy.

When selecting any specialty gas mixture, be sure you know what
type of standard the mixture you are purchasing will be analyzed
against. To ensure accuracy, insist on traceability to an SRM,
PRM or NTRM. Also remember that, as in the case of emission
monitoring, traceability and subsequent accuracy may be governed
by law.

You can ensure the integrity of your laboratory calibrations by
obtaining gas mixtures from reliable companies such as Scott
Specialty Gas, which has been the leading supplier of precursor
standards for NIST SRMs for more than 25 years, Praxair, the
second largest supplier of industrial and specialty gases to
chemical companies worldwide, and Airgas, which offers an
extensive line of high purity specialty gases as well as a full
range of specialty gas equipment specifically designed for use
with highest purity gases and high tolerance gas mixtures. Your
dedication to accurate calibrations will be rewarded many times
over in the precision of your measurements, and thus the quality
of your products, which can only make your customers smile.

For more information about EPA protocol gas accuracy, download a
copy of Accuracy Counts from http://www.scottgas.com.

This article is provided by Scott Specialty Gases. Scott
Specialty Gases, a leading global manufacturer of specialty
gases located in Plumsteadville, PA. More information on the
company can be found at http://www.scottgas.com.

This article is copyrighted by Scott Gases. It may not be
reproduced in whole or in part and may not be posted on other
websites, without the express written permission of the author
who may be contacted via email at
scottgas@digitalbrandexpressions.com.

About the Author R.L. Fielding has been a freelance writer for
10 years, offering her expertise and skills to a variety of
major organizations in the education, pharmaceuticals and
healthcare, financial services, and manufacturing industries.
She lives in New Jersey with her dog and two cats and enjoys
rock climbing and ornamental gardening.

Spam emails More free articles

Related articles


  1. Dear our beloved crying planet...
  2. Can sustainable development work? What then will be the impact on business and what will be the impa
  3. How You Can Give Better Holiday Gifts AND Be More Environmentally Friendly
  4. IT'S STILL A "JUNGLE" OUT THERE
  5. Avoiding Allergies by Use of the Right Native Plants in the Landscape
  6. Cottonwood "cotton" is flying/ Bad Company
  7. NLR: CONNECTICUT'S ONLY DEP PERMITTED MERCURY LAMP RECYCLER
  8. Can bamboo flooring really help save the worlds' environment?
  9. Real estate construction revolution - Epilogue
  10. Computer e-waste recycling now fueled by lack of Australian legislation.
  11. Earthquakes, Tsunamis, Mudslides: Extreme Events - What do they Mean?
  12. Ten Steps to Avoid Mold Problems and Lawsuits in the Rental of Residential and Commercial Real Estat
  13. Maguma has integrated support for the eBay Acellerator Toolkit for PHP (PHP-AT) in their PHP IDE Mag
  14. A Simple Way To Offset the Environmental Effects of Driving Your Car
  15. The Weather Forecast on Your Computer
  16. How Specialty Gases Differ from Industrial Gases
  17. How to Ensure Quality Control with CO2 Analytical Support
  18. The Cost of Inaccurate CEM Calibration Gases
  19. Mosquito Control: The Best Ways to Effectively Combat Mosquitoes
  20. Another Doomsday, Another Dollar: Shifting Science Towards Peace and Ecology
  21. Customer service 101- What You Absolutely Need to Know
  22. Employ passive solar energy and start saving electricity today.
  23. Dallas Contracting Co., Inc. Completes Concrete Aggregate Crushing Project
  24. There's a snake in the yard! -- What to do (and not do) when you see a snake.
  25. Environmentally-Friendly Earth Homes
More related feeds
Tracing the Accuracy of Calibration Gases
Regardless of how you use specialty gas mixtures to calibrate a laboratory instrument or monitor, the most important thing you can do to ensure the accuracy of your measurements is to ensure the accuracy of your gas mixture. ...

Bichloride ยป How Specialty Gases Differ from Industrial Gases
However, because purity is a health concern, a specialty pure CO2, in which all trace impurities have been carefully quantified, is needed to calibrate instruments used to monitor the purity of the bulk CO2. Specialty gas mixtures Many ...

Portable medical devices target battery accuracy - Electronic Products
For those supporting the medical profession with such products as portable devices, the corollary is โ€œBe as reliable as the technology allows you to be.โ€ Fuel gauge accuracy, underpinned by the impedance-tracking technology currently ...

Green Car Congress: Devil in the Details: NASA Satellite Joins The ...
Scientists have developed data algorithms and re-calibrated the instrument to partially compensate for the flaw. Microwave Limb Sounder (MLS) which measures emissions from ozone, chlorine and other trace gases, and clarifies the role of ...

Innovative Electronic & Electric Engineering: Transformer ...
Iris Power can provide support to assist in the installation and calibration of systems (if requested), and to help plan your outage by identifying the section(s) of the switchgear or bus duct that are at risk and require corrective ...

Jobs in Qatar - Doha : Instrumentation Technician | Bayt.com
Maintaining inspection, testing, defects, calibration records and related documentation. Qualifications * Diploma in Engineering with related experience. * 3 to 5 Years instrumentation control experience in gas turbine or aviation ...

BEFORE THE
to correct the amount of gas consumed based on temperature and. pressure. The TRACE AMR units are not physically compatible. with rotary meters where the TRACE units cover the index window. used to calibrate meters while in service. ...

Post-mission high accuracy position and orientation system invention
The VRS observables generator has as input data the pseudorange and carrier phase observables on two or more frequencies from N reference receivers, each tracking signals from M GNSS satellites. The VRS observables generator outputs a ...

Process Engineering | Sulzer Chemtech USA: Removing Liquid From ...
Design Considerations for High Liquid Rate Tray Applications ยท Tracing the accuracy of calibration gases ยท Clean-in-place operation for thin-cake filtration technologies ยท More White Papers ... Solid-Liquid Separation Solutions Process ...

Process Engineering | Dow aims to gas up methane conversion ...
Removing Liquid From Gas ยท Microturbine Testing ยท Tracing the accuracy of calibration gases ยท Top 10 tips for safely handling and using gas cylinders ยท Improve Dry Gas Seal Reliability in Centrifugal Compressors ยท More White Papers . ...